Rabu, 15 Juni 2011

PT. MADITECH MEDIKA FARMA



PT. MADITECH MEDIKA FARMA  is well established in   Medical,   Laboratory,   Instrument    and Hospital furniture.

Our core Bussiness included Radioterapy, Laboratory Pantology Clinic/Anatomy,   Operating  Theatre  equipment, X-Ray, Fisiotheraphy, USG, ECG, EEG, EMG,  CT-Scan,  MRI,  Treadmill,  Spirometre, Bonedencity, Dental Unit, Dental X-Ray, Intensive Care, Medical Ventilator, Medical Gas Piping, Electrical Hospital Bads, Medical Apparel & Textile, Emergency Product, Ambulance ….etc.

At present we are as Sole Agent for Radiotherapy as like as Cobalt 60 and Linex from Radon “TURKI”. We do supply the material/Equipment, but we are also involve in Design, Install, Service, Testing and commisioning all Product offered.  We are proffesional in our  field  and  offer  complete  program  for serve you with further details.

Our mission is to serve our customer by providing the reliable  and  high  quality  products  with  cost
effective and after sales services to meet their requirements and expectations.


PT. MADITECH MEDIKA FARMA
Jl. Raya Lenteng Agung No. 4
JAKARTA SELATAN 12610

Phone : 62+21+7873058,  7800375
Fax : 62-21-7873058

E-mail : marketing.maditech@gmail.com

Mobile : 081213786999
Mobile : 087878196999

High power monopolar and bipolar SURTRON 400 HP

SURTRON 400 HP

High power monopolar and bipolar

Can be used to execute monopolar and bipolar surgery in the many fields of application where it is requested high precision and reliability

Can be used to execute monopolar and bipolar surgery in the many fields of application where it is requested high precision and reliability

SURTRON® HP can be used to execute monopolar and bipolar surgery in the many fields of application where it is requested high precision and reliability.
TWIN OPERATIVE ACTIVITY
• Two output channels for monopolar cutting
• Two independent setting and output channels for the most frequent monopolar coagulation

CONTROLLED CUTTING PROCEDURES
• Enhanced cutting current for eschar free incision
• Cutting current with selectable coagulating property for bleeding controlled dissection
• Low capacitive coupling by slow BLEND current for endoscopic procedures

TWIN CONTROLLED COAGULATIVE PROCEDURES
• SPEEDY* coagulation and DEEP**coagulation available to two operators
• SPRAY coagulation available by hand switch or foot switch controls

WIDE BIPOLAR FEATURES

• Bipolar cutting current with selectable bleeding control
• Slow BLEND cutting current
• Separately activable Automatic Start/Stop coagulation (Detection system of tissue impedance)

SURGEON AND PATIENT TOTAL SAFETY
• Acceptability of contact impedance between patientbody and return electrode continuously watched by Skin Plate Electronic Control (SPEC)
• H.F. Leakage currents continuously monitored
• Mains fluctuation automatically compensated before to start the delivery of HF power

PERSONALIZED PROCEDURES
• Independent choise of coagulative currents and power levels by each of two operators
• Ten personal configurable and immediately recallable procedures

EXTENTION DRIVER AND INTERLOCK SIGNALS
• Drived output connection to external Argon Plasma unit and Smoke Evacuator unit

AUTOMATIC SELF DIAGNOSIS
• Automatic diagnostic control of the actual complete functionality of the electronic unit and the connected accessories with coded report of failures

*SPEEDY coagulation also said Fulgurate or Forced coagulation
**DEEP coagulation also said Pin Point, Dessicate or Soft coagulation
CONTROLS
Patient/Plate circuit monitoring
Output power monitoring
Self check control
H.F. Leakage currents control
Compensation of mains fluctuation

SAFETY
EN60601-1
EN60601-1-2
EN60601-2-2
Electrical Class: I CF
MDD 93/42/EC Class: II b


SURTRON®HP
300 HP
400 HP
Reference code
10400.801
10400.901
Maximum output power monopolar pure CUT
300 W→ 300 Ω
400 W → 300 Ω
Maximum output power monopolar cut-coag CUT80%
250 W → 300 Ω
300 W→ 300 Ω
Maximum output power monopolar cut-coag CUT60%
200 W → 300 Ω
250 W → 300 Ω
Maximum output power monopolar cut-coag CUT40%
150 W → 300 Ω
200 W → 300 Ω
Maximum output power monopolar cut ENHANCED
200 W → 500 Ω
250 W → 500 Ω
Maximum output power monopolar cut-coag BLEND
200 W → 300 Ω
25 W 0 → 300 Ω
Maximum output power monopolar coag SPEEDY
100 W → 500 Ω
120 W → 500 Ω
Maximum output power monopolar coag DEEP
100 W → 200 Ω
120 W  → 200 Ω
Maximum output power monopolar coag SPRAY
70 W → 2000 Ω
100 W → 2000 Ω
Maximum output power monopolar coag SPRAY ARGON
70 W → 2000 Ω
100 W → 2000 Ω
Maximum output power bipolar CUT
95  W → 150 Ω
95  W → 150 Ω
Maximum output power bipolar cut-coag CUT80%
95  W → 150 Ω
95 W → 150 Ω
Maximum output power bipolar cut-coag CUT60%
95  W → 150 Ω
95  W → 150 Ω
Maximum output power bipolar cut-coag CUT40%
60 W → 150 Ω
60 W → 150 Ω
Maximum output power bipolar cut-coag BLEND
90 W → 150 Ω
90 W → 150 Ω
Maximum output power bipolar coag COAG
70 W → 100 Ω
70 W → 100 Ω
Working frequency Monopolar / Bipolar
425 kHz / 525 kHz
425 kHz / 525 kHz
Patient circuit
F
F
Selectable input voltage
115- 230 Vac
115- 230 Vac
Mains frequency
50 - 60 Hz
50 - 60 Hz
Electrical input power
1000 VA
1000 VA
Weight Kgs
17.5
17.5
Size WxHxD mm
470x150x400
470x150x400

High power monopolar and bipolar SURTRON 300 HP

SURTRON 300 HP

High power monopolar and bipolar

Can be used to execute monopolar and bipolar surgery in the many fields of application where it is requested high precision and reliability



Can be used to execute monopolar and bipolar surgery in the many fields of application where it is requested high precision and reliability

SURTRON® HP can be used to execute monopolar and bipolar surgery in the many fields of application where it is requested high precision and reliability.
TWIN OPERATIVE ACTIVITY
• Two output channels for monopolar cutting
• Two independent setting and output channels for the most frequent monopolar coagulation

CONTROLLED CUTTING PROCEDURES
• Enhanced cutting current for eschar free incision
• Cutting current with selectable coagulating property for bleeding controlled dissection
• Low capacitive coupling by slow BLEND current for endoscopic procedures

TWIN CONTROLLED COAGULATIVE PROCEDURES
• SPEEDY* coagulation and DEEP**coagulation available to two operators
• SPRAY coagulation available by hand switch or foot switch controls

WIDE BIPOLAR FEATURES

• Bipolar cutting current with selectable bleeding control
• Slow BLEND cutting current
• Separately activable Automatic Start/Stop coagulation (Detection system of tissue impedance)

SURGEON AND PATIENT TOTAL SAFETY
• Acceptability of contact impedance between patientbody and return electrode continuously watched by Skin Plate Electronic Control (SPEC)
• H.F. Leakage currents continuously monitored
• Mains fluctuation automatically compensated before to start the delivery of HF power

PERSONALIZED PROCEDURES
• Independent choise of coagulative currents and power levels by each of two operators
• Ten personal configurable and immediately recallable procedures

EXTENTION DRIVER AND INTERLOCK SIGNALS
• Drived output connection to external Argon Plasma unit and Smoke Evacuator unit

AUTOMATIC SELF DIAGNOSIS
• Automatic diagnostic control of the actual complete functionality of the electronic unit and the connected accessories with coded report of failures

*SPEEDY coagulation also said Fulgurate or Forced coagulation
**DEEP coagulation also said Pin Point, Dessicate or Soft coagulation
CONTROLS
Patient/Plate circuit monitoring
Output power monitoring
Self check control
H.F. Leakage currents control
Compensation of mains fluctuation

SAFETY
EN60601-1
EN60601-1-2
EN60601-2-2
Electrical Class: I CF
MDD 93/42/EC Class: II b


SURTRON®HP
300 HP
400 HP
Reference code
10400.801
10400.901
Maximum output power monopolar pure CUT
300 W→ 300 Ω
400 W → 300 Ω
Maximum output power monopolar cut-coag CUT80%
250 W → 300 Ω
300 W→ 300 Ω
Maximum output power monopolar cut-coag CUT60%
200 W → 300 Ω
250 W → 300 Ω
Maximum output power monopolar cut-coag CUT40%
150 W → 300 Ω
200 W → 300 Ω
Maximum output power monopolar cut ENHANCED
200 W → 500 Ω
250 W → 500 Ω
Maximum output power monopolar cut-coag BLEND
200 W → 300 Ω
25 W 0 → 300 Ω
Maximum output power monopolar coag SPEEDY
100 W → 500 Ω
120 W → 500 Ω
Maximum output power monopolar coag DEEP
100 W → 200 Ω
120 W  → 200 Ω
Maximum output power monopolar coag SPRAY
70 W → 2000 Ω
100 W → 2000 Ω
Maximum output power monopolar coag SPRAY ARGON
70 W → 2000 Ω
100 W → 2000 Ω
Maximum output power bipolar CUT
95  W → 150 Ω
95  W → 150 Ω
Maximum output power bipolar cut-coag CUT80%
95  W → 150 Ω
95 W → 150 Ω
Maximum output power bipolar cut-coag CUT60%
95  W → 150 Ω
95  W → 150 Ω
Maximum output power bipolar cut-coag CUT40%
60 W → 150 Ω
60 W → 150 Ω
Maximum output power bipolar cut-coag BLEND
90 W → 150 Ω
90 W → 150 Ω
Maximum output power bipolar coag COAG
70 W → 100 Ω
70 W → 100 Ω
Working frequency Monopolar / Bipolar
425 kHz / 525 kHz
425 kHz / 525 kHz
Patient circuit
F
F
Selectable input voltage
115- 230 Vac
115- 230 Vac
Mains frequency
50 - 60 Hz
50 - 60 Hz
Electrical input power
1000 VA
1000 VA
Weight Kgs
17.5
17.5
Size WxHxD mm
470x150x400
470x150x400

Monopolar and Bipolar Radiosurgical unit with an emission of continuous or cycle timer power SURTRON FLASH 160 HF

SURTRON FLASH 160 HF

Monopolar and Bipolar Radiosurgical unit with an emission of continuous or cycle timer power

Electro‐surgical equipment at radio‐frequency (radio‐surgery).


Electro‐surgical equipment at radio‐frequency (radio‐surgery).

SURTRON® FLASH 160  HF , is a High Frequency RadioSurgical equipment which is suitable to precision monopolar and bipolar surgery and micro-surgery without tissue alterations.
SURTRON® FLASH 160  HF , can supply RF operative powers either for programmable time as short as hundreds of a second.
SURTRON® FLASH 160  HF  through its performances allows pure CUT,  cut-coagulation BLEND, incision with reduced prodution of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG, BIPOLAR coagulation and ABLATION. The digital reading of the delivered power and the overseeing through microcontroller of the operational functions, assure the absolute reliability of the conditions of job. In the bipolar coagulation modality can be activated a detection system of the tissues impedance with automatic activation and automatic stop when it coagulation is achieved (AUTOSTART – AUTOSTOP).
SURTRON® FLASH 160  HF , allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the output functions as well as the delivery of output power, allows to implement the surgical operation without turning away the surgeon attention from the surgical field.
CONTROLS
Patient/Plate circuit monitoring
Output power monitoring
Self check control

SAFETY
EN60601-1 
EN60601-1-2 
EN60601-2-2 
Electrical Class: I CF
MDD 93/42/EC Class: II b


Main Features
SURTRON® FLASH
160 HF
Reference code
10300.201
Max output power CUT (1)
150 W→ 250 Ω
Max output power BLEND (1)
100 W → 200 Ω
Max output power ENHANCED (1)
100 W→ 250 Ω
Max output power FORCED COAG
100 W → 150 Ω
Max output power SOFT COAG
80 W → 100 Ω
Max output power BIPOLAR COAG
60 W→ 100 Ω
Max output power BIPOLAR ABLATION (1)
60 W→ 100 Ω
Working frequency
600 kHz
Working frequency ((1)FUNCTION ONLY)
4.0 MHz
RF power pulse emission time
10 – 990 ms
RF power pulse interval
1 – 9
Patient circuit
F
Selectable input voltage
115 - 230 Vac
Mains frequency
50 - 60 Hz
Electrical input power
350 VA
Weight Kgs
6
Size WxHxD mm
370x144x319



Monopolar and bipolar with an emission of continuous or cycle timer power SURTRON FLASH 200

SURTRON FLASH 200

Monopolar and bipolar with an emission of continuous or cycle timer power

Supplies RF operative powers either for programmable time as short as hundreds of a second.

Supplies RF operative powers either for programmable time as short as hundreds of a second.

SURTRON® FLASH, can supply RF operative powers either for programmable time as short as hundreds of a second.
SURTRON® FLASH, through its performances allows pure CUT,  cut-coagulation BLEND, incision with reduced prodution of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG, BIPOLAR coagulation and ABLATION. The digital reading of the delivered power and the overseeing through microcontroller of the operational functions, assure the absolute reliability of the conditions of job.
In the bipolar coagulation modality can be activated a detection system of the tissues impedance with automatic activation and automatic stop when it coagulation is achieved (AUTOSTART – AUTOSTOP).
SURTRON® FLASH allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the output functions as well as the delivery of output power, allows to implement the surgical operation without turning away the surgeon attention from the surgical field.
CONTROLS
Patient/Plate circuit monitoring
Output power monitoring
Self check control

SAFETY
EN60601-1
EN60601-1-2
EN60601-2-2
Electrical Class: I CF
MDD 93/42/EC Class: II b


SURTRON® FLASH
120
200
Reference code
10300.101
10300.401
Max output power CUT
120 W → 250 Ω
200 W → 250 Ω
Max output power BLEND
90 W → 200 Ω
120 W → 200 Ω
Max output power ENHANCED
90 W → 250 Ω
120 W → 250 Ω
Max output power FORCED COAG
80 W → 150 Ω
150 W → 150 Ω
Max output power SOFT COAG
60 W → 100 Ω
90 W → 100 Ω
Max output power BIPOLAR COAG
60 W → 100 Ω
80 W → 100 Ω
Max output power BIPOLAR ABLATION
--
--
Working frequency
600 kHz
600 kHz
RF power pulse emission time
10 – 990 ms
10 – 990 ms
RF power pulse interval
1 – 9
1 – 9
Patient circuit
F
F
Selectable input voltage
115 – 230 Vac
115 – 230 Vac
Mains frequency
50-  60 Hz
50 - 60 Hz
Electrical input power
300 VA
350 VA
Weight Kgs
6
6
Size WxHxD mm
370x144x319
370x144x319



Monopolar and bipolar with an emission of continuous or cycle timer power SURTRON FLASH 200

SURTRON FLASH 200

Monopolar and bipolar with an emission of continuous or cycle timer power

Supplies RF operative powers either for programmable time as short as hundreds of a second.


Monopolar and bipolar with an emission of continuous or cycle timer power SURTRON FLASH 120

SURTRON FLASH 120

Monopolar and bipolar with an emission of continuous or cycle timer power

Supplies RF operative powers either for programmable time as short as hundreds of a second.

Supplies RF operative powers either for programmable time as short as hundreds of a second.

SURTRON® FLASH, can supply RF operative powers either for programmable time as short as hundreds of a second.
SURTRON® FLASH, through its performances allows pure CUT,  cut-coagulation BLEND, incision with reduced prodution of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG, BIPOLAR coagulation and ABLATION. The digital reading of the delivered power and the overseeing through microcontroller of the operational functions, assure the absolute reliability of the conditions of job.
In the bipolar coagulation modality can be activated a detection system of the tissues impedance with automatic activation and automatic stop when it coagulation is achieved (AUTOSTART – AUTOSTOP).
SURTRON® FLASH allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the output functions as well as the delivery of output power, allows to implement the surgical operation without turning away the surgeon attention from the surgical field.
CONTROLS
Patient/Plate circuit monitoring
Output power monitoring
Self check control

SAFETY
EN60601-1
EN60601-1-2
EN60601-2-2
Electrical Class: I CF
MDD 93/42/EC Class: II b

SURTRON® FLASH
120
200
Reference code
10300.101
10300.401
Max output power CUT
120 W → 250 Ω
200 W → 250 Ω
Max output power BLEND
90 W → 200 Ω
120 W → 200 Ω
Max output power ENHANCED
90 W → 250 Ω
120 W → 250 Ω
Max output power FORCED COAG
80 W → 150 Ω
150 W → 150 Ω
Max output power SOFT COAG
60 W → 100 Ω
90 W → 100 Ω
Max output power BIPOLAR COAG
60 W → 100 Ω
80 W → 100 Ω
Max output power BIPOLAR ABLATION
--
--
Working frequency
600 kHz
600 kHz
RF power pulse emission time
10 – 990 ms
10 – 990 ms
RF power pulse interval
1 – 9
1 – 9
Patient circuit
F
F
Selectable input voltage
115 – 230 Vac
115 – 230 Vac
Mains frequency
50-  60 Hz
50 - 60 Hz
Electrical input power
300 VA
350 VA
Weight Kgs
6
6
Size WxHxD mm
370x144x319
370x144x319