SURTRON 300 HP
High power monopolar and bipolar
Can be used to execute monopolar and bipolar surgery in the many fields of application where it is requested high precision and reliability
Can be used to execute monopolar and bipolar surgery in the many fields of application where it is requested high precision and reliability
SURTRON® HP can be used to execute monopolar and bipolar surgery in the many fields of application where it is requested high precision and reliability.
TWIN OPERATIVE ACTIVITY
• Two output channels for monopolar cutting
• Two independent setting and output channels for the most frequent monopolar coagulation
CONTROLLED CUTTING PROCEDURES
• Enhanced cutting current for eschar free incision
• Cutting current with selectable coagulating property for bleeding controlled dissection
• Low capacitive coupling by slow BLEND current for endoscopic procedures
TWIN CONTROLLED COAGULATIVE PROCEDURES
• SPEEDY* coagulation and DEEP**coagulation available to two operators
• SPRAY coagulation available by hand switch or foot switch controls
WIDE BIPOLAR FEATURES
• Bipolar cutting current with selectable bleeding control
• Slow BLEND cutting current
• Separately activable Automatic Start/Stop coagulation (Detection system of tissue impedance)
SURGEON AND PATIENT TOTAL SAFETY
• Acceptability of contact impedance between patientbody and return electrode continuously watched by Skin Plate Electronic Control (SPEC)
• H.F. Leakage currents continuously monitored
• Mains fluctuation automatically compensated before to start the delivery of HF power
PERSONALIZED PROCEDURES
• Independent choise of coagulative currents and power levels by each of two operators
• Ten personal configurable and immediately recallable procedures
EXTENTION DRIVER AND INTERLOCK SIGNALS
• Drived output connection to external Argon Plasma unit and Smoke Evacuator unit
AUTOMATIC SELF DIAGNOSIS
• Automatic diagnostic control of the actual complete functionality of the electronic unit and the connected accessories with coded report of failures
*SPEEDY coagulation also said Fulgurate or Forced coagulation
**DEEP coagulation also said Pin Point, Dessicate or Soft coagulation
• Two output channels for monopolar cutting
• Two independent setting and output channels for the most frequent monopolar coagulation
CONTROLLED CUTTING PROCEDURES
• Enhanced cutting current for eschar free incision
• Cutting current with selectable coagulating property for bleeding controlled dissection
• Low capacitive coupling by slow BLEND current for endoscopic procedures
TWIN CONTROLLED COAGULATIVE PROCEDURES
• SPEEDY* coagulation and DEEP**coagulation available to two operators
• SPRAY coagulation available by hand switch or foot switch controls
WIDE BIPOLAR FEATURES
• Bipolar cutting current with selectable bleeding control
• Slow BLEND cutting current
• Separately activable Automatic Start/Stop coagulation (Detection system of tissue impedance)
SURGEON AND PATIENT TOTAL SAFETY
• Acceptability of contact impedance between patientbody and return electrode continuously watched by Skin Plate Electronic Control (SPEC)
• H.F. Leakage currents continuously monitored
• Mains fluctuation automatically compensated before to start the delivery of HF power
PERSONALIZED PROCEDURES
• Independent choise of coagulative currents and power levels by each of two operators
• Ten personal configurable and immediately recallable procedures
EXTENTION DRIVER AND INTERLOCK SIGNALS
• Drived output connection to external Argon Plasma unit and Smoke Evacuator unit
AUTOMATIC SELF DIAGNOSIS
• Automatic diagnostic control of the actual complete functionality of the electronic unit and the connected accessories with coded report of failures
*SPEEDY coagulation also said Fulgurate or Forced coagulation
**DEEP coagulation also said Pin Point, Dessicate or Soft coagulation
CONTROLS
Patient/Plate circuit monitoring
Output power monitoring
Self check control
H.F. Leakage currents control
Compensation of mains fluctuation
SAFETY
EN60601-1
EN60601-1-2
EN60601-2-2
Electrical Class: I CF
MDD 93/42/EC Class: II b
Output power monitoring
Self check control
H.F. Leakage currents control
Compensation of mains fluctuation
SAFETY
EN60601-1
EN60601-1-2
EN60601-2-2
Electrical Class: I CF
MDD 93/42/EC Class: II b
SURTRON®HP | 300 HP | 400 HP |
Reference code | 10400.801 | 10400.901 |
Maximum output power monopolar pure CUT | 300 W→ 300 Ω | 400 W → 300 Ω |
Maximum output power monopolar cut-coag CUT80% | 250 W → 300 Ω | 300 W→ 300 Ω |
Maximum output power monopolar cut-coag CUT60% | 200 W → 300 Ω | 250 W → 300 Ω |
Maximum output power monopolar cut-coag CUT40% | 150 W → 300 Ω | 200 W → 300 Ω |
Maximum output power monopolar cut ENHANCED | 200 W → 500 Ω | 250 W → 500 Ω |
Maximum output power monopolar cut-coag BLEND | 200 W → 300 Ω | 25 W 0 → 300 Ω |
Maximum output power monopolar coag SPEEDY | 100 W → 500 Ω | 120 W → 500 Ω |
Maximum output power monopolar coag DEEP | 100 W → 200 Ω | 120 W → 200 Ω |
Maximum output power monopolar coag SPRAY | 70 W → 2000 Ω | 100 W → 2000 Ω |
Maximum output power monopolar coag SPRAY ARGON | 70 W → 2000 Ω | 100 W → 2000 Ω |
Maximum output power bipolar CUT | 95 W → 150 Ω | 95 W → 150 Ω |
Maximum output power bipolar cut-coag CUT80% | 95 W → 150 Ω | 95 W → 150 Ω |
Maximum output power bipolar cut-coag CUT60% | 95 W → 150 Ω | 95 W → 150 Ω |
Maximum output power bipolar cut-coag CUT40% | 60 W → 150 Ω | 60 W → 150 Ω |
Maximum output power bipolar cut-coag BLEND | 90 W → 150 Ω | 90 W → 150 Ω |
Maximum output power bipolar coag COAG | 70 W → 100 Ω | 70 W → 100 Ω |
Working frequency Monopolar / Bipolar | 425 kHz / 525 kHz | 425 kHz / 525 kHz |
Patient circuit | F | F |
Selectable input voltage | 115- 230 Vac | 115- 230 Vac |
Mains frequency | 50 - 60 Hz | 50 - 60 Hz |
Electrical input power | 1000 VA | 1000 VA |
Weight Kgs | 17.5 | 17.5 |
Size WxHxD mm | 470x150x400 | 470x150x400 |